Why did the customer contact us?

The customer had mice in their attic.

Solutions provided:

Facia board will be composite that is installed on front and rear of home behind gutters and freeze board underneath gutters attached to brick. Facia board and freeze board will be sealed after attachment to brick on the underside with clear sealant. Soffit to be replaced on front and rear of home to composite and will have 12 2 inch port vents installed on rear soffit and 12 2 inch port vents installed on front soffit. Rake boards to be replaced with composite on the left side of home and right side of home. Rake boards will be sealed on the underside with clear sealant after installed. Above itemized composite boards are to be installed after removal of old damaged boards on front rear left and right side of home at rake board, soffit, fascia board, and freeze board. These boards will be painted custom to match the rest of home color on original work order. These prices are for material only, all labor has been included in existing work order , Color will be heritage cream by berger trim coil. Replace 40 foot of freeze board/trim board under soffit on front and rear of home, replace 50 foot of rake board on left side of home, replace 40 foot of fascia board on front and rear of home, replace 20 foot of soffit on front of home. Front of home has 12 2 inch port vents in soffit and will need to be bored and reinstalled with new vents. Gutters on the front and rear of home we need to be removed and reinstalled and re-sloped. All wood replaced will be painted best to match is heritage cream by berger trim coil. Install RVG over attic fan on rear roof, seal around pipe entry points through brick on left side of home. Remove old/soiled fiberglass blown insulation, stare fab treat attic to kill any bacteria, parasites, or mites. Check HVAC flex lines and seam tape penetration points. Hole found at entry of attic at flex duck and hard duck intercept. Blow in or 38 cellulose insulation to current standard. After all insulation is removed conduct inspection of wiring in the attic for any further damage. Mist spray stare fab treatment on three levels are home throughout home in each room to kill any bacteria that may be present per request by client. Add Leaf Solutions to uncapped gutters on front and rear of gutters. Screen 2 vents on the left side of home.

Our Affiliates